Sandhya Enterprises
Request A Quote
  • Number #1 Provider

    of Industrial Solution
  • Contact:

    +91 - 9652998932
  • Email:

    info@sandhyaflex.com

Insulating Rubber Mat

Insulating Rubber Mat :

An ISO-9001:2015 certified Co., Sandhya Enterprises is engaged in Polymer and Rubber Industry from over last three decades.

At metro Corporation (Formerly Tata rubber Corporation), we offer premium grade safety mats for electrical purposes.

The safety Mats are manufactured with the material having high di-electric strength and a capacity to with stand KV up to 3.3Kg, 11.0KV and 33.0KV. Apart from insulation mats manufacturing, we manufacture several other Industrial Products such as hosepipe, rubber sheets, neoprene, silicon, nitride and other synthetic rubber profiles. The insulating rubber mats ensure the safety of workers while working with high or low voltage electrical equipment. Usually comedies Mats are supposed to be laid on the floor closely to the electrical apparatus; L.T & H.T control panels, switchboards, fuse boxes, switchgear electrical bus bars and heavy machinery. Moreover, the insulation mats are compulsory to be installed in industrial premises to ensure the safety of workers involved in any operation related to electricity generation, transmission or distribution.

Dielectric safety Mats we supply comply with the Indian/ National/ International standards of the American Society for Testing and Materials (ASTM), International Electro Technical Commission (IEC) and Bureau of Indian Standards (BIS).

We do not compromise with the safety and offers safety mats that provide best safety from electric shocks.

Above all, we are dedicated to continuously develop our tools, techniques and products to provide a greater impact on workers safety.

Electrical Insulation Mat for Electrical Purposes IS: 15652-2006 (Latest)

Enlarge

Insulating Rubber Mat

Electrical insulation mat for electrical purposes are used to provide safety to the electricians by offering insulation against electricity and preventing electrical shocks. The mats are effective against both AC and DC installations. The synthetic insulation mats or poly elector safe mats are available for both HT and LT Voltage Panels. They are suitable for system voltages up to 66kV AC and 240 V DC. These insulating mats provide safety as well as ergonomics benefits.

Regardless of the type of industry, insulating mats can be used in an electrical shop for the safety of technicians in danger as well as a factory. These electric shock-proof mats and electrical insulation mats provides protection from electrical shock along with working as a cushion for the workers for ergonomical purposes. Moreover, they mats provides cushion surface for the workers to stand for longer time without complaining of ergonomical fatigue. These insulating mats for electrical panels are very useful in industries where any sort of electrical work is involved.

Considering the present scenario of Indian Industries, not much attention is paid towards the safety of the workers. Often, many companies forget that ensuring the safety of employees do not require too much efforts. The mats we offer serve an excellent option to introduce a safe working environment on the shop floor. Apart from safety, it also enhances the working conditions by providing the required cushioning to the technicians who are working on the shop floor having a standing job.

Sandhya Enterprises has a history of manufacturing the finest insulating mats in India having optimum quality and safety standards. Moreover, the electrical insulation mats will make the manufacturing facility shockproof and safe.

Several areas where these electrical mats find their application are electricity control panels, HT & LT panels, energy sub-stations and power control rooms among others.

Classification

The electrical rubber insulation mats are in accordance with BIS Standard 15652-06. It is divided into three classes based on Voltage Ratings. The three classes differ depending on thickness of mats, Voltage Grade, proof voltage and break down voltage.

Electrical Insulation Mat Voltage Ratings

Class Thickness Grade KV Proof voltage B/Down voltage
A 2.0 mm 3.3 10KV/3 minutes 30 KV
B 2.5 mm 11 22KV/3 minutes 30 KV
C 3.0 mm 33 36KV/3 minutes 65 KV

Construction: Made from Highly Electrical resistant Elastomers, free from any insertions. "Elastomer" (a generic term that includes rubbers, Latex and elastomeric compounds that may be natural synthetic or a mixture or a combination of both). High Voltage Resistant Electrical Insulation Matting is made up of 100% virgin compound.

  • Colour: Any colour without metallic derivatives.
  • Surface:Anti-skid (rough on top & smooth at bottom to avoid slippery effects).
  • Size: Can be in standard size- 1mtr x 2mtr or in Long rolls form.
  • Working Temperature Range: -10°C to +60°C.
  • Marking: Mats should be marked with Class, Lot No. and Manufacturer Identity.
  • Packing: Should be packed in Gunny /Jute /Hessian /HDPE bags to avoid any mechanical damage to the mats.

Silent Features of Electrical Insulating Mats :

  • High Di-Electric Strength up to 65KV.
  • Complies to IS:15652-2006 (latest).
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Superseding The Electric Shock Proof Rubber mats for Electrical Purposes IS:5424.
  • Resistant to Fire.
  • Hold Excellent Physical Properties so that can withstands movement of instrument involved in Electrical Equipment & Foot Traffic. Resistant to wide range of Acids, Alkalis & Oils.
  • Withstands both AC & DC electrical installations.
  • Can be Pasted/Installed on Floor if required, not mandatory. Water & moisture proof.
  • Exhibit good Elongation & Tensile Strength Properties.